RSS Feed
News
Dec
21
MicroSurvey STAR*NET 7.2.2
Posted by Brian Sloman on 21 December 2012 01:42 PM

MicroSurvey Software Inc. is pleased to announce STAR*NET 7.2.2, the latest service pack update to its industry-leading STAR*NET least squares network adjustment suite.  This update includes a new 10-day, fully-functional STAR*NET-PRO demo period and a new STAR*Leica DBX conversion utility for importing Leica data, as well as fixes to several important issues when importing MicroSurvey FieldGenius, Leica DBX, Trimble JobXML, and Trimble TSC data files.  This is a FREE update for any STAR*NET users who already use STAR*NET 7.2, or to any STAR*NET users who have a valid (non-expired) Maintenance Subscription Support Program. 

 

New Features in STAR*NET 7.2.2:

Fully Functional Demo
A fully-functional 10-day demo period has been added, during which you can run the fully-featured STAR*NET-PRO edition plus all of the STAR*NET data conversion utilities.
After 10 days, you can continue to run the feature-limited STAR*NET-DEMO edition, which has all the capabilities of STAR*NET-PRO but is limited to an adjustment of 10 stations, 100 observations, and 15 GPS vectors.
Leica DBX Conversion Utility
A new standalone Leica DBX conversion utility (licensed separately) is now available for importing both conventional and/or GPS data from Leica DBX databases.
Several fixes have been implemented since STAR*LeicaDBX v7.2.0.12 which was previously available as a zip download from our website, see details below.

Defects Fixed in STAR*NET 7.2.2:

  • [D5582] Adjustment - A crash could occur while adjusting a network during Cholesky Factorization, this has been fixed.
  • [D5845] General - When setting/changing an output filename in the GPS Importer, Point Reformatter, DXF Exporter, or the Conversion Utilities, the default filename may be scrolled to the side making it only partially visible.
  • [D5836] GPS Importer - FieldGenius baseline importer can now read the Reference ID and position data which was recently added to the raw raw file as "--GNSS Statistics RT: ..." comment records, and it will parse these if the raw file does not contain a BP record to define the base point prior to the rover measurements (ie, when using an NTRIP or GPRS connection, connecting to a permanent base, etc).
  • [D5788] Listing - The Listing Index Tree may not jump to the correct line if the "Copy of Input Data File(s)" project listing option is enabled and the input data file(s) are Unicode.
  • [D5795] Listing - The "95%" column header in "Adjusted Elevations and Error Propagation" section in the listing file may not appear.
  • [D5780] Network License - When using a network USB license, on exiting from the conversion utilities the license was not immediately released.
  • [D5036] STAR*FieldGenius - Angles-only Multiset records cause "ERROR: Slope Distance (SD) field missing", this is now accepted as valid input data and the distance is exported as "?".
  • [D5420] STAR*FieldGenius - Multiset records may cause "ERROR: Rod Height (HR) field does not match value in previous LineOfSight (LS) record" when using the "Output as 2D Data" option, this has been corrected.
  • [D5420] STAR*FieldGenius - Multiset records with varying target heights cause "ERROR: Rod Height (HR) field does not match value in previous LineOfSight (LS) record", this has been changed from an Error to a Warning.
  • [D5547] STAR*FieldGenius - Projects in Bearings cause "ERROR: Invalid Field Value (AD)", this is now accepted as valid input data.
  • [D5843] STAR*FieldGenius - When using the "Output as 2D Data" option, the 2D coordinate C records occur after a .3D inline command.
  • [D5749] STAR*JobXML - Prism Offset values were not applied to EDM distance measurements.
  • [D5790] STAR*JobXML - Atmospheric Correction values were not applied to EDM distance measurements.
  • [D5584] STAR*JobXML - Distances are always stored internally in the JobXML file as Meters, but they are now automatically scaled and output as Meters/FeetInt/FeetUS depending on project settings.
  • [D5583] STAR*JobXML - Conventional stakeout records are not exported. All terrestrial observations with valid Circle or MTA elements are now accepted.
  • [D5486] STAR*JobXML - Line Staking records are not eported. All terrestrial observations with valid Circle or MTA elements are now accepted.
  • [D5487] STAR*JobXML - Some GPS vectors (with Method=GpsRTKControlPoint and Classification=Normal) are not exported to the data file. All vectors with valid ECEFDeltas elements are now accepted.
  • [D5543] STAR*JobXML - Some GPS vectors (with Method=GpsRTKQuickMark) are not exported to the data file. All vectors with valid ECEFDeltas elements are now accepted.
  • [D5544] STAR*JobXML - Negative PPM values cause "ERROR: PPM element has invalid value", this is now accepted as valid input data.
  • [D5806] STAR*JobXML - Dialog options are not be saved when the utility is closed via the X button in the top-right corner.
  • [D5585] STAR*LeicaDBX - Points without a defined elevation were exported without a z-coordinate value, causing "ERROR: Unrecognized Input" during adjustment. 2D points are now exported with a "?" z-coordinate value.
  • [D5831] STAR*LeicaDBX - Averaged GPS measurements were being converted to a fixed coordinate (C record) and commented vectors (G0/G1/G2/G3 records). This has been reversed such that the vectors are no longer commented, but the coordinate is. Additionally, a comment has been added to the end of the C records to indicate their Class, which is useful when reviewing data that contains multiple observations of a point plus its averaged coordinate.
  • [D5832] STAR*LeicaDBX - GPS antenna height measurements were being output to the G1 records in the selected unit. Like all values in the G1 record, they are now always output in meters.
  • [D5835] STAR*LeicaDBX - GPS vector covariances were not computed correctly, results now match the same data imported as Leica SKI ASCII format.
  • [D5837] STAR*LeicaDBX - Browse button doesn't start in the expected folder, it now starts in the same location as the current database folder.
  • [D5844] STAR*LeicaDBX - If a required Geoid (*.gem) and/or CSCS (*.csc) file is not found when importing a database, the selected Output data file becomes locked until the utility is restarted.
  • [D5548] STAR*TSC - Pressing the "Convert" button can cause an "Unable to Open Log File, Conversion not performed!" message.
  • [D5567] STAR*TSC - Pressing the "View Log" button can cause the program to stop responding.

 

Download Link

MicroSurvey STAR*NET 7.2.2 Install (includes all conversion utilities): click here

Existing MicroSurvey STAR*NET users with a current maintenance plan may need to use the USB License Manager application to update their USB License Key(s) before this version can be run. If your maintenance plan has expired, please call MicroSurvey Software Inc. at 1-800-668-3312 or 1-250-707-0000 or contact your local MicroSurvey dealer to renew it.

For demonstration purposes, MicroSurvey STAR*NET can be run for 10-days as the fully-featured STAR*NET-PRO edition, and beyond that as the limited 10-station STAR*NET-DEMO edition.  All of the conversion utilities are also unlocked during this 10-day demo period.

 

Additional Online Resources

MicroSurvey STAR*NET Product Website: click here

MicroSurvey STAR*NET Online Training Movies: click here

MicroSurvey STAR*NET 7 Release Notes: click here

MicroSurvey STAR*NET 7 Upgrade Notes: click here

MicroSurvey STAR*NET 7 Known Issues: click here

 

Additional Supporting Applications

MicroSurvey USB License Manager (included in the STAR*NET 7 install): click here

MicroSurvey USB Network License Server (must be purchased separately): click here


Read more »



Dec
12
MicroSurvey FieldGenius 2012 Version 6.0.4 Is Released
Posted by John Coldrick on 12 December 2012 02:34 PM

MicroSurvey FieldGenius Version 6.0.4.2

MicroSurvey Software Inc. is proud to announce the release of this latest version of FieldGenuis2012.

New Features for FieldGenius 2012 Version 6.0.4.2:

Important NOTEGeoMax Users, do not download this version.  Please wait as we will be releasing a hot-fix for this shortly.  For now, please use versiom 6.0.3.5.  Do not install this version (6.0.4.2) as there is a fatal communication issue, and you will not be able to connect.

 

  •    Many new features including:

    • Added support for more GNSS receivers,
    • Check Point Routine update - you will now remain in the routine after checking a point,
    • Pentax W800 total station driver improvements,
    • and much more.
  •    New Coordinate Systems and Geoid Models:

    • Hungary Coordinate Systems,
    • OSGM02 Geoid model for Ireland is now available for download,
    • We also added subsets of EGM08 specifically cut out for Columbia, Mozambique, and Panama.  These are all available to download for free at our web site.
  •     Many bug fixes:

    • Fixed a bug related to the left/right buttons on the Staking Alignment toolbar.  
    • Fixed a bug where after you switched the project's units to feet and then pressed the Save As Default button, your project would still be in metres.  It now changes to feet.
    • Fixed a bug where closing the Staking toolbar when staking an alignment did not return you to the Stake Alignment dialog.  It now does.
    • and many more (see release notes for details).


Upgrade Cost?

This is a free upgrade to customers who already have a licensed version of FieldGenius 2012 Version 6.0.0 or higher.



Please review the Release Notes for more details on this new version.


Click here to view the Release Notes

 

MicroSurvey FieldGenius 2012 Version 6.0.4 Install Web Page

Click here to access the FieldGenius 2012 6.0.4 downloads page

 


MicroSurvey FieldGenius 2012 Product Website:


Click here to access FieldGenius 2012 Product Page

 




Read more »



Nov
30
MicroSurvey Layout 1.0.3.5 is now available
Posted by John Coldrick on 30 November 2012 11:47 AM

Version 1.0.3.5

Important Note:  This release addresses significant performance issues that affected the previous version.  Please update to this version immediately.

 

MicroSurvey Software Inc. is proud to announce our latest software release built specifically for the construction and MEP markets.

MicroSurvey Layout is a simple to use locating program designed specifically for construction layout and MEP contractors. Used on its own, or in conjunction with Point Prep, MicroSurvey Layout gives you all the tools you need to layout your points accurately and easily. Also included is an as-built mode to document work that has been completed, or to measure and record points needed for earthwork quantities.

Available Platforms

MicroSurvey Layout is available for the following devices:

  • All Windows Mobile 6 Devices including:
  • Juniper Systems Allegro MX
  • Juniper Systems Archer
  • Juniper Systems Mesa
  • Nautiz X7
  • Leica iCON CC50
  • Leica TS15, CS10 and CS15.

MicroSurvey Layout can also be installed on your desktop computer including all tablet computers running Windows operating systems. The following devices are supported:

  • Desktop computers running Windows XP, Vista, Windows 7 and Windows 8.
  • Laptop computers running Windows XP, Vista, Windows 7 and Windows 8.
  • Tablet computers running Windows 7
  • Leica iCON CC60/61
  • Algiz 7

Special Feature

MicroSurvey Layout also includes support for the Leica 3D Disto.

More Information and Demo

For more information about this product, please visit the MicroSurvey Layout website.

To download a demo, please fill out the following demo request form or contact your dealer.


Read more »



Nov
8
MicroSurvey Evidence Recorder 9.0.3 Is Released
Posted by John Coldrick on 08 November 2012 01:43 PM

MicroSurvey Evidence Recorder Version 9.0.3.5

MicroSurvey Software Inc. is proud to announce the release of this latest version of Evidence Recorder.

New Features for Evidence Recorder Version 9.0.3.5:

  •    Many new features including:

    • Addded the ability to copy and edit pre-existing coordinate systems.
    • Leica GeoCOM and OWI licenses are no longer required to run Evidence Recorder on a Leica CS25.
    • Leica CS25:  We added Long Range Bluetooth support.
    • and much more.
  •     Many bug fixes:

    • Fixed a bug related to the Trimble Recon and Windows Mobile 6.0 (classic).
    • Fixed a bug releated to the rotate, translate, and scale function.  The Cancel button did not cancel.
    • and many more (see release notes for details).


Upgrade Cost?

This is a free upgrade to customers who already have a licensed version of Evidence Recorder Version 9.0.0 or higher.



Please review the Release Notes for more details on this new version.


Click here to view the Release Notes.

 

Evidence Recorder Version 9.0.3 Install Web Page

Click here to access the Evidence Recorder 9.0.3 downloads page.

 


Evidence Recorder Product Website:


Click here to access Evidence Recorder Product Page.

 




Read more »



Nov
7
MicroSurvey FieldGenius 2012 Version 6.0.3 Is Released
Posted by John Coldrick on 07 November 2012 10:24 AM

MicroSurvey FieldGenius Version 6.0.3.5

MicroSurvey Software Inc. is proud to announce the release of this latest version of FieldGenuis2012.

New Features for FieldGenius 2012 Version 6.0.3.5:

  •    Many new features including:

    • Addded the ability to copy and edit pre-existing coordinate systems.
    • Leica GeoCOM and OWI licenses are no longer required to run FieldGenius on a Leica CS25.
    • Leica CS25:  We added Long Range Bluetooth support.
    • NavCom:  Added support for StarFire over IP.
    • and much more.
  •    New Coordinate Systems and Geoid Models:

    • Columbia has 4 new coordinate systems added.
    • Latvia LV98 geoid model is now availabale for download.
    • We also added subsets of EGM08 specifcially cut out for Columbia, Panama, Guatemala, and Hungary.  These are all available to download for free at our web site.
  •     Many bug fixes:

    • Fixed a bug releated to the rotate, translate, and scale function.  The Cancel button did not cancel.
    • Fixed a nearest search staking bug.  This only applied to non-robotic total stations and the project had to be in feet.  The next nearest point presented wasn't the next nearest.
    • and many more (see release notes for details).


Upgrade Cost?

This is a free upgrade to customers who already have a licensed version of FieldGenius 2012 Version 6.0.0 or higher.



Please review the Release Notes for more details on this new version.


Click here to view the Release Notes.

 

MicroSurvey FieldGenius 2012 Version 6.0.3 Install Web Page

Click here to access the FieldGenius 2012 6.0.3 downloads page.

 


MicroSurvey FieldGenius 2012 Product Website:


Click here to access FieldGenius 2012 Product Page.

 




Read more »



Oct
31
MicroSurvey Point Prep 2013
Posted by Brian Sloman on 31 October 2012 09:58 AM

MicroSurvey is pleased to announce the release of MicroSurvey Point Prep 2013. MicroSurvey Point Prep – built for construction layout and MEP contractors – helps prepare all of the field data needed on a job site, before leaving the office.

Open AutoCAD® .dwg and .dxf files with Point Prep and use the many built-in tools to help you hide or eliminate unnecessary data. Point Prep makes it easy to create coordinates, input plan data from paper plans, create point patterns, compute offset points, create DTM models and prepare as-built drawings. MicroSurvey Point Prep syncs easily with MicroSurvey Layout so points and drawing data can be easily used at the job site for layout.

MicroSurvey offers free trial versions for all of its major software – download MicroSurvey Point Prep 2013 today!


Release Notes

Click here to view the complete MicroSurvey Point Prep 2013 Release Notes.

Initial product release
MicroSurvey Point Prep 2013 is a desktop application designed to perfectly complement your MicroSurvey Layout or Leica iCON data collection software. Quickly transform a drawing file into a MicroSurvey Layout or Leica iCON project, upload and download between Point Prep on your desktop computer and Layout on your data collector, and import Layout projects into an annotated Point Prep drawing to review your field measurements.

Download MicroSurvey Point Prep 2013

MicroSurvey Point Prep 2013 (v13.0.0)

MicroSurvey Point Prep 2013 can be activated with the purchase of a USB license key.

MicroSurvey Point Prep 2013 can also be run in a 30-day, fully functional trial version for demonstration purposes.


Download Supporting Applications

Microsoft ActiveSync & Windows Mobile Device Center (free, required for data transfer between Point Prep and Layout).

MicroSurvey Transfer (included in the full install, free data transfer utility for MicroSurvey Layout users, requires Microsoft ActiveSync or Windows Mobile Device Center).

MicroSurvey USB License Manager (included in the full install, free utility for activating or updating your USB license key).

MicroSurvey USB Network License Server (requires a password to install, must be purchased separately).


Read more »




Help Desk Software by Kayako Fusion