FieldGenius 2004 History
MicroSurvey has been releasing regular service packs for FieldGenius 2004. With easy internet installations, and single CAB files installs (depending upon your model) we believe it serves our customer's best interest by releasing improvements and corrections as soon as possible.
Version 1.0.10 - Updated - November 17, 2004
|
|
|
|
-
Updated the Topcon, Sokkia, Leica, Nikon, and Trimble drivers to correct problems where the instrument capabilities were not being reported correctly. For example, this will fix problems where FieldGenius would not display the reflectorless measurement mode when connecting to some Topcon instruments, even though the instrument supports it.
|
|
Version 1.0.9 Changes:
|
|
|
|
|
|
|
|
|
|
|
|
|
-
GPS offsets – On the GPS measurement screen you can now specify an offset direction, horizontal offset and vertical offset.
GPS Localization – Added a new toggle to the GPS Measurement screen named “Use for Local Transformation”. If this is turned on, the point will automatically be added to the local transformation control list as a measured point.

GPS Localization – When editing the control and you use the new “Use for Local Transformation” option, FieldGenius will automatically display the closest point to your measured point in the control column.
|
|
|
|
Note Field – If a large string was entered it would wrap around into the Point ID field, this has now been corrected.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
Instrument Settings – This has now been updated so when the Instrument Settings button is pressed they will see the following screen which allows them to change settings specific to the instrument type they've chosen.

Instrument Type None – A new instrument type has been introduced. If the user selects None, then the instrument toolbar will not be displayed on the map screen.
|
Version 1.0.8 Changes:
- AP records written to the raw file for re-transformed GPS positions now retain the point description.
|
|
|
-
Error information will now be written to the raw file in the form of notes with regards to occupying a point. This will occur if you specify a backsight point and measure a distance. Following is an example:
OC,OP100,N 5523097.8740,E 311564.9840,EL399.3867,--
SP,PN101,N 5523168.8710,E 311529.9120,EL401.1876,--NAIL
BK,OP100,BP101,BS333.42395,BC0.00000
--Occupy Check
-- Observed Values: HA 0°00'00.0" VA 90°00'00.0" SD 52.000m HD 52.000m
-- Distance Calculated: 79.187m
-- Distance Error: -27.187m
-- BS Elevation: 401.188m
-- BS Elevation Error: -1.801m
|
|
|
|
|
|
- New DAP build that fixes problems when FieldGenius tried to create a Machine ID.
|
|
-
Added keyboard shortcuts for FieldGenius menu items. The user can now press the letter “H” to open the main menu in FieldGenius. Furthermore, all the buttons in the Main Menu are now mapped to keys for easy navigation. For example, if you press the number 3 on your keyboard it will open the Survey Menu. Or pressing “M” will take you back to the Map view. For non keyboard devices, this can be disabled by turning off "Menu Shortcuts" in program settings.
|
- DXF Export now supports export of Text labels for Point IDs, Elevations and Notes.

|
- Fixed ambiguity of prism offsets with Topcon non-robotic instruments.
|
- Topcon non-robotic driver now support s motor positioning functions.
|
- Fixed the management of target height units when re-coordinating points from the raw file.
|
|
 |

Unlike the old tool, you can now switch between deflection angles and directions on the fly.
|
|
|
- When a project was opened it always defaulted to the lowest available point number in the project database. We have now updated FieldGenius so it scans the raw file and finds the last SS record and sets the Next ID equal to the last SS ID+1.
|
-
New datum support for the United Kingdom (2002), Africa , Pacific Islands , Russia , Asia and miscellaneous United States regions. Note this will not affect customers in North America .
|
-
Coordinate Points that are created from instrument measurements are tagged with the attribute SurveyRoleType: measured. The northing,easting,elevation of Measured coordinates cannot be edited in the Store/Edit Point Dialog.
|
|
-
The resection routine has been updated so when the user is satisfied with their results and presses the Store Pnt button, they will automatically be taken to the Occupy Point screen. The Occupy point screen will use the computed resection point for the setup and use the BS point specified in the resection routine. The user does not have to re-measure the backsight as we will use the original measurement from the resection.
|
|
Version 1.0.7 Changes:
- Nikon A10 total station: Problem with Metric/Feet units depending on Old Series/New Series driver.
|
- Coordinate DXF - I found that the first line I coordinated started with a point "0", then incremented to the next available point number.
|
- Traverse Report - When I press this button I get an instant crash in both the emulator and on the iPAQ.
|
- Password Problem: problem fetching device ID from a Ranger.
|
- Password problem:problem fetching device ID from a SD card.
|
- Occupy Point will now provide the option to store a backsight point in the case where a backsight bearing is specified, but a distance is also measured.
|
- Fixed problem with FieldGenius looking for non-existent project XML or DXF files on new projects.
|
- Topcon robot and RC2 equipment combination now works with Turn to Point feature.
|
- Activating Staking toolbar will no longer cause a Zoom to project extents.
|
- "New look" Progress Meter.
|
- Improved performance for drawing arcs.
|
- Zone Number field added to Automap (column/field 32). This field can be used to assign (LandXML) zone numbers based on the automap description code.
|
- GPS observed positions can be adjusted with updated transformation parameters.
|
Version 1.0.6 Changes:
- Important note: if you are running on an iPAQ (either HP or Compaq) then when you install this update the program may ask for a new password. We were using a Compaq supplied function to get the serial number of the device, but it is unreliable, so we have dropped it. The program will only find a serial number from a Compact Flash card, or if you are running Pocket PC 2003, from a Secure digital card.
|
- MicroSurveyIM keyboard was removed from the Panasonic Toughbook installs. If you have a previous installation of the program, please erase the file "MicroSurveyIM.dll" from the \Storage Card\MicroSurvey FieldGenius\Programs directory and from the \Windows directory. This file makes the Panasonic unstable.
|
- The raw file editor now supports horizontal scrolling so you can view the entire record.
|
- Setting the Hz circle on Trimble 5600's was not working
|
- Fixed parsing of GPS messages on all models.
|
- DXF Entities - (lines & arcs) can now be coordinated into the project database. Select the entity and use the new Add to Database button on the Line Toolbar.
|
- Updated Sokkia - Set Advanced driver
|
- Updated Surface Manager and Surface Settings dialog
|
- Improvements where made for handling extra large DXF files
|
- There are now two Toughbook installs. There is a Windows CE 3.0 install, and a special Toughbook PocketPC install. This is necessary because we do not want to install the MicroSurveyIM.dll file on the Toughbook.
|
- The Panasonic PocketPC version is now working perfectly.
|
- Updated Parcel Manager Dialog - includes function to coordinate parcel data to the project database, and the ability to set individual parcel visibility.
|
- Update Coordinate points manager - adds functionality to control visibility of CgPoints (from LandXML files) by set.
|
- Default SideShot mode is now set to Auto (faster storing of sideshot points with fewer prompts).
|
- A small test project is installed called FG Sample that contains some points and linework.
|
- An extra prompt was added after doing an Occupy Point to remind you to take a backsight shot. Several customers were going straight into the staking routine without establishing a backsight.
|
| |
Version 1.0.5 Changes:
- Added new total station instrument driver, Nikon - New Series.
|
- Additional program initialization fix-ups to address reports of FG2004 not starting on Toughbook with older ROM revision (version L10F or older).
|
- GPS support for CDMA and GSM modems (Leica only)
|
- GPS support for logging raw carrier phase data to a file (Leica only)
|
- Updated GPS function and profile tables (GPSFUNC2004.DBF and GPSPROF2004.DBF)
|
- New Build available for Topcon FC1000 (SH4 processor)
|
Version 1.0.4 Changes:
- Fix for Leica TPS Series (GSI) - Setting plate with non-zero value was not operating correctly.
|
- Fix for Leica TPS Series - Incorrect vertical angle could be obtained if the instrument stack was not reset.
|
- Fix for Leica TPS Series - Level bubble dialog now enabled for instruments without ATR and instruments which have ability to send information of inclined axis.
|
- Fix for Leica TPS Series - Search and motorized function are now properly disabled in FieldGenius for instruments which do not support those features.
|
- Fix for Leica TPS Series - FG was not correctly identifying a horizontal angle measurement error and allowed an invalid measurement to be used.
|
- Bug - When user changed Point ID during S+ sequence, the Next ID was not being set on the main topo toolbar
|
- Feature - When Exporting LandXML file, a note on a dbf point will be written to the CgPoint Description field (if not already in use).
|
- Bug - GPS NMEA model was not working with Garmin devices.
|
- Bug - Sokkia Set Basic driver was not handling feet units correctly.
|
- Bug - After staking the second point in a series, the field showing the design point ID on the Stake Point dialog would be blank rather than showing the previously staked point ID.
|
- Bug - Station Offset Tool - Once you have specified a baseline for this routine. If you want to work on a different baseline and enter the end points to define it, the function will continue to use the original baseline points. There is no way to purge it other than to use the line picker or close FieldGenius and re-open the project.
|
- Bug - When GPS is selected instrument type, the Survey menu will not display Occupy Pt, Check Backsight, Benchmark Shot and Traverse Report options
|
- Feature - Menu dialog 'Close' button has been renamed to 'MAP'
|
- Feature - Stake settings now includes option checkbox to Store Stake Point
|
- Bug - Reprocess Raw File - When a user makes an edit to the raw and reprocesses it, the descriptions will be blanked out for all the points.
|
- Bug - Edit Raw File - Insert LS record is overwriting raw file information. When you use this function, and press the save button. The "-- Inserted LS" note overwrites the row the user had highlighted.
|
- Feature - Project distance Units cannot be changed after a project is created
|
- Added additional note to the backsight check routine to include the observed values in the raw file.
|
- Added additional note to the occupy point routine to include the observed values in the raw file.
|
- Bug - The dashed line connecting the occupied and backsight point, could be drawn incorrectly if one of the two points was invalid.
|
- Bug - Resolved build/configuration issues for FG2004 on older iPAQ models, Toughbook CE and Toughbook Pocket PC models
|
Version 1.0.3 Changes:
- RC2 - turn to point disabled when RC2 used
- Bug - Set Plate in RC2 - this function was not working
- Increased height of staking toolbar by 5 pixels to better fit navigation icons
- "Robotic License Required" now appears on Search button if module not licensed
- Store CgPoint to coordinate database is now an option when you pick a CgPoint
- Bug - View control buttons Zoom Window, Pan, Zoom +/- were not always displaying correct state
- Bug - FieldGenius startup application fixes install location in registry correctly now
- Improved readability of license information on "About FieldGenius" screen
- Increased intelligence on point chooser toolbar. It has been modified so that if a DXF point or XML point is selected, where a project database point is required (e.g. Occupy Point), the user will be given the option to store that point in the database
Version 1.0.2 Changes:
- Improved DXF import
- Fix when switching from GPS to TS mode
- Scrolling info area was not zooming when tapped
- Real Time DTM was not re-computing with each shot
- Volume Calculation between surfaces screen added
|