MicroSurvey
CAD 2005 - SP1.1 Release Notes
November 18, 2005
|
Output scale factor wasn't displaying scaled
values in the curve inverse dialog, but was at the command line. This has been fixed. |
|
Added functionality so when the COGO rotation
angle option is used, the user will see a note at the command line that a
rotation is being applied when bearings are entered using COGO. |
|
2 point inverse information that is displayed at
the command line has been updated to fit on one line. |
|
On the Cad Curves computation dialog, if the
output scale factor is turned on, we will display a note in the dialog
Applying Output Scale Factor (###.###) |
|
Improved MSCAD functions that are affected by the
input or output scale factors so reminder is displayed in the command line
and in the view log. OS indicates
that an output scale was applied, where as IS indicates that an input scale
was applied. |
|
Open loop closure with first backsight being a
direction would cause a problem. This
has been fixed. |
|
Attempting to spline a POLYLINE or LWPOLYLINE
that has only 2 vertices would cause a crash, this is now fixed. |
|
Added support to allow the registration of MSCAD 2005
for educational purposes. |
|
ADT improvements to prevent a crash that could
occur if the user started an ADT function such as "Set Coordinate"
and closed the ADT editor before completing the command. |
|
Fixed the problem that would cause thin line weights
to not appear thin when plotted. |
|
Extended Entity Data attached to Group objects
was lost after the drawing was saved, this is now fixed. |
|
Corrected a problem that could crash MSCAD when
you tried to move the ruler in the MTEXT dialog. |
|
Corrected a problem that would sometimes reset
the base point of a user defined hatch. |
|
Sometimes the wrong house was being placed from
the library, even though the correct one was selected. This problem has been corrected. |
|
SMI Raw File Import TR shots stored in the raw
file will now be displayed as a traverse TR shot in MSCAD when imported. Before this change they were displayed as
sideshot SS record which still computed correct coordinates when the file
was processed. |
|
New houses added to the library that were
originally drawn at other than 0,0 were being
inserted based upon 0,0 and could be shifted off the lot. This is fixed. |
Following is a complete list of commands that are now affected by the input scale factor toggle.
===============
COGO
The input scale toggle should be
applied everywhere that distances are used in cogo.
cogo, regular options: TR, DD, DA, elsewhere?
cogo, curve (dialog and command line)
cogo, chord bearing
cogo, bearing offsets
100
100g6
(including the vertical distance)
1..2
c(100)
100s
100i
100fsg6
1..2/2
1..2+A
c(3ms+4i) the
scale will be applied to the final answer
1..2+3m does
not convert the 3 to meters, it just uses the 3
A
Vertical angle toggle
Batch COGO
===============
CAD Lines | Curves
CAD Line Computations dialog, Tangent
to Arc button
CAD Curve Computations dialog, Compound
button.
CAD Curve Computations dialog, Reverse
button.
CAD Curve Computations dialog, Two
Tangent button.
CAD Curve Computations dialog, Tangent
button.
CAD Curve Computations dialog, Tangent
button.
CAD Line Computations dialog, Traverse button
===============
Menu: MsCogo->Curve
on two tangents
registered command: ("arc_on_two_tangents")
Menu: MsCogo->Line Tangent to Curve
Registered command: ("ms_line_tangent_curve")
Menu: MsPoints->Compute Points->Compute Points on an Object
Registered command: ("ms_comp_points_on_line_curve")
Menu: MsPoints->Compute Points->Compute Points by Station/Offset/Elevation
Registered command: ms_comp_points_stn_offset
Menu: MsPoints->Compute Points->Compute Points by Turned Angle
Registered command: ms_comp_points_turned_angle
Menu: MsCogo->Reverse or Compound Curve
Registered_command: reverse_curve
Menu: MsCogo->Curve Off One Tangent
registered_command: arc_on_tangent
===============
Older style manual traverse entry (using dialog boxes or command line, rather than ADT
entry). (hzdist,
vtdist, slpdist, vtdist, perpoff, paroff)
===============
Note that using ADT raw editor NEVER applies input scale factor.
Following is a complete list of commands that are now affected by the output scale factor toggle.
Registered command: perp_ties
Registered command: areas
Registered command: legaldesc
Registered command: cogo, all options (including 2 and 3 pt inverses)
Registered command: inverse
Registered command: connect_points
Registered command: radial_inverse
Registered command: ms_pt_adjust
Registered command: ms_coordinate
old style manual raw entry (dialogs or command line)
CAD Curve Computations dialog
CAD Line Computations dialog
Registered command: fastarea
Registered command: right_of_way
Registered command: angles_right_report
Registered command: stake_report
new_stake_report
dialog, Add Shots button